Acceleration filter time
- Menu: 4.9.14-10.21-1
- Index: 8713.2[0]
Description
The parameter is displayed if the following conditions are met:
- The encoder uses one of the following interfaces for data transmission: sine/cosine, HIPERFACE®, RS485, SSI or SSI combi
- The encoder is used to determine the speed/acceleration.
Time interval used to determine the average speed change from the encoder signal.
The filter time is used to compensate for physical fluctuations in the acceleration, or to reduce quantization errors of the evaluation method.
The filter time has an impact on the response time of the acceleration functions (safety sub-function SLA) and must be taken into account in the safety assessment.
The default value of the filter time is 50 ms.